3F MEDICAL SYETEM

Technical Specifications

 

Safety

Meet requirement of IEC60601-1

 

Dimension and weight

Package Size: 240 x 320 x 330 (mm)

GW: 3.6 KGS(with battery)

 

Power Supply

AC input: 100~240VAC(10%), 50/60Hz(±3Hz), 40VA

Vehicular DC input: 9V~15V

Battery input: 6.4V~8.4V

up to 5/10 hours working time, less than 4/8 hours charging time

 

Operation Environment

Temperature: 0~40(32~104)

Humidity: ≤70%,non-condensing

 

Patient Range

Adult, Pediatric and neonatal

 

Performance Specification

Display: LED+3.2” graphic TFT LCD

Resolution: 320x240

Trace: 1/2 waveforms

Sweep Speed: 12.5mm/s, 25mm/s

Alarm indicator light

Alarm sound

Alarm information and alarm parameter flash

Net Interface: RJ45

Battery: Rechargeable

Storage review: 4000 groups

Alarm: 3-level audible and visual alarm

Recorder (optional): Thermal array

Record speed: 25mm/s, 50mm/s

CMRR: >89dB

S-T detection: YES

Measurement range: -1.0mV~1.0mV

Arrhymia analysis: YES

Alarm: YES, audible and visual alarm, alarm events recallable

 

Stand

 (See home page)

 

Options

Thermal Recorder, EZ Mount, i-Care Tablet PC, Wall Mounting, Trolley,

 

ECG Standard Configuration

Lead: 3-lead/ 5-lead optional

Lead Selection: Monitoring lead/ 12 lead system

ECG Waveform: 1 channel

Gain Selection: x0.5, x1

Scan Rate: 12.5mm/s, 25mm/s

Heart rate range: 0

Precision: 1BPM or 1%, 20~350BPM(±3%)

 

 

 

Respiration

Method: RA-LL impedance

Measurement Range: 0, 10~120rpm

Resolution: 1rpm

Accuracy: 2% or 2rpm, whichever is greater

 

NIBP

Method: Oscillometric

Operation Modes: Manual/Automatic/Continous

Measurement Unit: mmHg/kPa optional

Measurement Type: SYS

Measurement Range:

Adult mode

SYS: 40~255(mmHg)

DIA: 10~195(mmHg)

MEAN: 20~215(mmHg)

 

Pediatric mode

SYS: 40~200(mmHg)

DIA: 10~150(mmHg)

MEAN: 20~165(mmHg)

 

Neonatal mode

SYS: 40~135(mmHg)

DIA: 10~110(mmHg)

MEAN: 20~125(mmHg)

 

Over-pressure Protection: YES

Resolution: 1mmHg

Alarm: Systolic, Diastolic and Mean

Data storage/review: 4000 group blood pressure value

 

Temperature

Scale:

Measurement Range: and optional

20~50

Resolution: 0.1

Channel: 1 channel

 

SpO2(3F)

Range: 0~100%

Resolution: 1%

Range of pulse rate: 25~250BPM

Pulse rate precision: 1BPM

 

SpO2(Nellcor / Masimo)

Range: 0~100%

Resolution: 1%

Range of pulse rate: 20~300BPM

Pulse rate precision: 1%

DIAMEAN

 

 

 

 

 

 

 

 

 

 

 

   
   
 
 
 
Options
SD Card
SD Card
Enlarge full disclosure data storage .Convenient for exporting and saving patient info
Long Life Li-ion Battery
Long Life Li-ion Battery
Lasting time up to 10 hours
Temp Probe
Temp Probe
Skin-surface type / Rectal type
Thermal Recorder
Thermal Recorder
Thermal recorder supporting 3-waveform and 4-record mode
Bracket
Bracket
Multi-selection for various sites
Trolley
Transfer easily between multi-section offices

 

 

 

 

 

 

IRIS PATIENT MONITOR DOWNLOADS:

> IRIS Spec Sheet.pdf

> IRIS Service manual.pdf